Sample calculations:Uin = 4.94V, Uout = 4,05V, Rk = 10000 (10K)Rx = 10000 * (4.94 – 4.05)/4.05 = 2197 ohmWhen you are using the additional temp
Attention !The sensors’ calibration doesn’t write down the settings in the device’s memory, it only generates the calibration curve! Intake air tempe
InjectorsThe DET3 device has 2 power outputs with the 5A load each. Because of this, we can connect to each of them 4 high-resistance injectors or two
ATTENTION! Exceeding the outputs’ load limit (5A) will lead to the damage of the power outputs, what may cause the permanent opening of the connected
Injection modeThere are three working modes available:1) Batch fire output 1 – in this mode, all injectors (not more than 4) are connected to the Powe
CrankingParameters responsible for the engine’s start-up can be defined in the Cranking menu. The basic setting is the injectors’ opening time during
Afterstart enrichmentDuring the engine’s start-up the Afterstart Enrichment phase begins. It is in this phase that the additional enri
Warmup enrichmentEnrichment of the fuel dose in the function of coolant temperature is used to compensate the fact, that in low te
Acceleration enrichmentDuring acceleration (sudden opening of the throttle) significant pressure change takes place in the
The next important tables are Acceleration enrichment RPM factor and Acceleration enrichment TPS factor table. The first defines the way in which
ATTENTION !The Digital ECU Tuner 3 device is designed only for motor sports and cannot be used on public roads!The installation of the device may be c
Narrowband O2 sensor (NGO)DET3 device has the possibility to change the contents the mixture on the basis of readings from the narrowband O2 sensor
Tables switch inputDET 3 device has Tables Switch Input (Pin 2), which is primarily used to switch the table set (it allows the user to prepare two se
Boost control Using DET3 in Fuel Implant mode gives the possibility of controlling the boost pressure both in open loop and closed loop. In order to
Parameter descriptionEnable boost controlActivates boost control functionality.Max OverboostMaximum pressure allowed in kPa. Above this value the cont
P, I, DControllers PID factors (kP, kI, kD), determining how “strong” influence has each of the regulators members.Integral windupMaximum saturation o
Launch control Launch control function (starting procedure) is used to set the optimal starting engine speed (for a given RPM the ignition is cut off)
Wiring diagram for frequency input: Frequency In(10) Pullup (8)DET 3ActivationSwitch (SW1)
Parametric outputParametric output is used for the parametric control of the external actuators. Depending on the electric current required by the ac
Parametric output configuration To configure the parametric output, choose the parameter window (Setup/Paramteric output configuration). In the config
Factory MAP/MAF sensorIn Fuel Implant technology controlling the injectors is fully based on DET3 device. However the factory ECU has to constantly re
Table of contentsThe installation of the software...
LogSaving values of the sensors and parameters like time of opening the injectors, enrichments or actual RPM, in a log is an key activity in order to
Freq. Out (Frequency Out) Current frequency in Hz on Frequency Out outputInjection Out Time of opening of the injectors in msWarmup(warmup enrichment)
Ignition control Ignition control is made analogically to the standard mode of the devices work. More information on this topic can be found in the DE
Work mode sequence of DET3 Fuel ImplantCurrent working mode of DET3 Fuel Implant is displayed on the Windows client status bar. The device can be runn
Speed Density algorithmIn Speed Density algorithm the injector opening time is calculated based on a physical model using absolute pressure in the ma
Alpha-N algorithmAlgorithm Alpha-N is similar to Speed Density algorithm, however the pressure in the manifold is not taken into account, additionally
ECUMASTER DET3 „FUEL IMPLANT” TECHNOLOGYBy using the „Fuel Implant” technology, it is possible to directly control the injectors opening time by using
The installation of the softwareIn order to use the Fuel Implant technology you should install the right software for Win
+12VInj.Bank 2Connecting the deviceOn the Picture below there is a typical example of the DET3 device’s connection in the
ConfigurationAttention!Disconnect all injectors before setup the configuration! Basic parameters of the configuration of the device can be found in th
Enable Baro correctionTurning this option on makes the device taking into the consideration the correction of the current barometric pressure. The ba
Sensors’ configurationTo make sure the device is working properly and it correctly calculates the fuel dose, you should connect and calibrate the foll
Commentaires sur ces manuels